PRESSURE STEAMERS
Approval _______________________________
Quantity _______________________________ FCSI Section ____________________________
Date __________________________________
PRESSURE STEAMERS
MODELS:
2 OR 3 COMPARTMENTS, CABINET MOUNTED ELECTRIC STEAM GENERATOR 24, 36 OR 48 KW, 36” WIDE CABINET BASE
2 Compartments
PEM-24-2 PEM-36-2 PEM-48-2
3 Compartments
PEM-24-3 PEM-36-3 PEM-48-3
Cleveland Standard Features I 5 psi Operating Pressure in cooking compartments
I Mechanical interlock prevents unlatching door while compartment
is pressurized
I Timers, one per compartment, are mechanical style with
audible signal
I Thermostatic Trap vents cooking compartment automatically I Steam Inlet Valves and Exhaust Valves interlocked for
synchronous action
I 8 psi Compartment Safety Valve
I Capacity per compartment for eight, 12” x 20” x 2 1/2” deep
Cafeteria Pans, or four, 18” x 26” Bun Pans
I Heavy Duty, free floating, cast aluminum compartment doors I Compartment Door Hinges have adjustable hinge pins and
self-lubricating bushings
I Door Gasket replaceable without tools
I Pressure Gauge for compartment operating pressure
I Compartment Slide Racks are removable without tools, for
easy cleaning
I Type 430 Stainless Steel: external enclosure, Table Top and I I I I I I I I
Ë
Short Form Specifications
eight gage plate cooking compartments Modular Cabinet Base with Hinged Doors High efficiency Electric Steam Generator with Automatic Water Fill on start-up Automatic Water Level Control System with Low Water Power Cut-off Circuit Steam Generator equipped with High-limit Pressure Safety Switch and Safety Valve Automatic Steam Generator (boiler) Blowdown allows intermittent control, complete with additional Manual Drain Valve Steam Generator Pressure Gauge 6” Stainless Steel Legs with level adjustment and flanged feet Single Cold Water Connection (no hot water required) Secondary Low Water Cut-Off, factory installed (CALE) (Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
I Standard Voltage 208-240 volts, 60 hz, single phase, three
Shall be _____ Compartments, CLEVELAND, Pressure Steamer, Model PEM- _____ - _____ , Electric Steam Generator, _____ kw, _____ volts, _____ ph, three wire. Each Cooking Compartment equipped with: 60 Minute Timer; Heavy-duty, free floating Door with Safety Interlock; and synchronous operating Steam Inlet and Exhaust/Drain Valves. Solid State Controls operate Water Level and Steam Generator (boiler) Safety Functions. Automatic Steam Generator (boiler) Blowdown with additional Manual Drain Valve.
Ë Kettle Interconnecting Kit (IMK)
Ë Stainless Steel base Frame (FSS)
Ë Stainless Steel gas flue cover, insulated (SSF) Ë Special compartment Slide Racks
Ë 12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep Ë Intermediate Pull-Out Shelf (POS)
Ë Spray Head with flexible Hose (SH) Ë Voltages, other than standard
wire I All Major Components are serviceable from the front of unit
Ë Water Filters
Ë Correctional Packages
Options & Accessories Ë Automatic Steam Inlet and Exhaust Operation (AT-2): includes 60 minute Automatic Timers and Manual Bypass Ë 15 psi for Kettle Operation, includes Power Take-Off (PTO)
1333 East 179 St.,
Tel: 1-216-481-4900
Web Site: www.ClevelandRange.com
Cleveland, Ohio, U.S.A. 44110
Fax: 1-216-481-3782
Email:
[email protected]
SECT.
VI
1
PAGE 0609
• Each compartment has capacity for:
• •
Cafeteria Pans or Eight, 12˝ x 20˝ x 21⁄2˝ Six, 12˝ x 20˝ x 4˝ Cafeteria Pans or Four, 12˝ x 20˝ x 6˝ Cafeteria Pans or Bun Pans Four, 18˝ x 26˝ Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with those codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, NSF, ASME/N.Bd., CSA.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows: TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
ELECTRIC
KW Volts Watts Ph Amps Wire 24
208
21,500 1
103.4
2
220
24,000 1
109.1
2
240
24,000 1
100.0
2
440
20,200 1
45.9
2
480
24,000 1
50.0
2
208
21,500 3
59.7
3
220
24,000 3
63.1
3
240
24,000 3
57.8
3
440
20,200 3
26.5
3
480
24,000 3
28.9
3
600
24,000 3
23.1
3
360
21,500 3
34.5
4
380
24,000 3
36.5
4
415
24,000 3
33.4
4
KW Volts Watts 36 208 32,200 220 36,000 240 36,000 440 30,200 480 36,000 600 36,000 360 32,200 380 36,000 415 36,000 48 208 42,900 220 48,000 240 48,000 440 40,300 480 48,000 600 48,000 360 42,900 380 48,000 415 48,000
Ph 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
Amps Wire 89.5 3 94.6 3 86.7 3 39.7 3 43.4 3 34.7 3 51.7 4 54.8 4 50.1 4 119.2 3 126.1 3 115.6 3 52.9 3 57.8 3 46.2 3 68.9 4 73.0 4 66.9 4
Cleveland Range reserves right of design improvement or modification, as warranted.
WATER
C
1/4˝ NPT Cold Water Inlet 35 psi minimum 60 psi maximum
DRAINAGE
D
The Floor Drain must be located outside the confines of the equipment base. 1 1/2˝ I.P.S. common drain. Do not connect other units to this drain. Do not use PVC pipe for drain.
CLEARANCE Right - 3”, Left - 3”, Rear - 3” (12” on control side if adjoining wall or equipment is over 30” high for service access)